Unimark Sprite Manuel de l'opérateur Page 32

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 36
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 31
Sprite Installation and Operator’s Manual REV D1 Page 32 of 36
AEA Related LCD Alert Messages
Refer to following table for a list of the messages displayed, their description, and the appropriate corrective action:
LCD
Messages
Description Corrective Action
(ALERT CLEAR)
Illogical command.
Where cc = the unrecognized command
Unit received an illogical command, or a
non-AEA (non-supported) command.
Press ONLINE/ENTER push-button twice to
clear the message; or message will be cleared
upon receiving any valid AEA command.
Error in ticket print message.
Where cc = the element where the error
was detected
Unit detected an error in the ticket print
message.
Press ONLINE/ENTER push-button twice to
clear the message; or message will be cleared
upon receiving any valid AEA command.
Print/Encode error.
Unit has detected an error during the print
and/or encode process.
Press ONLINE/ENTER push-button twice to
clear the message; or message will be cleared
upon receiving any valid AEA command.
Missing PECTAB.
Where # = the PECTAB name being
referenced by the ticket print message
Ticket print message is referencing a
PECTAB not currently in memory.
Press ONLINE/ENTER push-button twice to
clear the message; or message will be cleared
upon receiving any valid AEA command.
Check-In or Revalidation in progress.
Unit could not process command because it is
in a Check-In or Revalidation state.
Press ONLINE/ENTER push-button twice to
clear the message; or message will be cleared
upon receiving any valid AEA command.
Error in PECTAB load.
Where ee = the element where the error
was detected
Unit detected a format error in the PECTAB
load.
Press ONLINE/ENTER push-button twice to
clear the message; or message will be cleared
upon receiving any valid AEA command.
Memory access error during object load.
There is not enough memory available load
objects such as a PECTABs or Logos.
Press ONLINE/ENTER push-button twice to
clear the message; or message will be cleared
upon receiving any valid AEA command.
Incorrect stock type selected.
Where s = the stock type number in the
ticket print message
Ticket print message is requesting a stock
type not currently configured for the selected
Bin.
Press ONLINE/ENTER push-button twice to
clear the message; or message will be cleared
upon receiving any valid AEA command.
O n l i n e
E R R 2 c c
O n l i n e
E R R 3 c c
O n l i n e
E R R 5
O n l i n e
E R R 6 #
O n l i n e
E R R 7
O n l i n e
E R R 8 e e
O n l i n e
E R R S s
O n l i n e
E R R 9
Vue de la page 31